HJE11F-M-120A
Feature Description

》120A/48VDC switching capability

》Very minimal power consumption from the coil

》Contact Load Maximum Switching DC 110VDC/60A

》4KV dielectrics strength coil to contact

》Outline dimensions(47.2×33.2×22)mm

》RoHS,CQC compliant

Product Details
Contact Data
Rated load(FLA)120A/48VAC
Contact form1A & 1B
Contact materialAgSnO2
Initial contact resistance2mΩ(0.1A@6vdc)
Max.switching current120A
Max.switching voltage110VAC
Max.switching power5760VA
Electrical endurance

120A/48VDC 10000 times with resistive load

60A/110VDC 5000 times with resistive loa

Mechanical endurance1x106 ops


COIL POWER

Coil typePulse durationPower consumption
SingleMin.50ms3W
DualMin.50ms6W



CHARACTERISTICS

Insulation Resistance1000MΩ(at 500VDC)

Dielectric Strengt

Coil To Contact4000VAC 1 min
Across Open Contact2000VAC 1 min
Operate TimeMax.20ms
Release TimeMax.20ms
Shock Resistance Functional100m/s 2(10g)
Shock Resistance Destructive1000m/s 2(100g)
Ambient Temperature-40~85℃
Humidity98%RH, +40℃
Vibration Resistance10-55Hz, 1.5mm(DA)
TerminationPCB
Unit Weight85g
ConstructionDust Protected


COIL DAT

Nominal coil voltage6Vdc9Vdc12Vdc24Vdc
Operating Voltage VDC≤4.2≤6.3≤8.4≤16.8
Coil Resistance (Ω±10%)@23℃Single coil resistance12Ω27Ω48Ω192Ω
Dual coil resistance2×6Ω2×13.5Ω2×24Ω2×96Ω


Ordering Information

华锦英文HJE11F-M-120A-2.jpg

Dimensions (mm)

华锦英文HJE11F-M-120A-3.jpg

Precautions

1. All relays must be shipped in the closed state. The relay may become open during shipping or assembly, therefore, it is recommended to set the relay state to off through the power supply.

2. In order to keep the relay in the open or closed state, the coil voltage needs to reach the rated voltage, and the electronic pulse needs to be 5 times the working time to ensure the correct state conversion. Do not apply voltage to T1, T2, and T3 on the coil for more than one minute to prevent the coil from being damaged.

3. The relay has polarity distinction. If the polarity required by the user does not match the data, it should be specially mentioned when ordering.

4. Relays should be handled with care when entering the factory for inspection and use to prevent damage from affecting parameters. Products entering the factory for destructive inspection must be strictly differentiated from normal products and must not be installed and used.

Contact Us

If you are interested in our products, or have any questions about our products, please feel free to contact us, we will serve you wholeheartedly